# Copyright 1999-2023 Gentoo Authors # Distributed under the terms of the GNU General Public License v2 EAPI=8 PYTHON_COMPAT=( python3_{10..12} ) inherit bash-completion-r1 desktop flag-o-matic linux-info optfeature inherit python-single-r1 systemd tmpfiles toolchain-funcs udev wrapper xdg MY_P=${P/_/-} DESCRIPTION="Network-UPS Tools" HOMEPAGE="https://networkupstools.org/" if [[ ${PV} == *9999 ]] ; then EGIT_REPO_URI="https://github.com/networkupstools/${PN}.git" inherit git-r3 else SRC_URI="https://networkupstools.org/source/${PV%.*}/${MY_P}.tar.gz" KEYWORDS="~amd64 ~arm64 ~x86" fi S="${WORKDIR}/${MY_P}" LICENSE="GPL-2" SLOT="0" IUSE="gpio cgi doc ipmi serial i2c +man snmp +usb modbus selinux ssl tcpd test xml zeroconf python monitor systemd" RESTRICT="!test? ( test )" REQUIRED_USE=" monitor? ( python ) python? ( ${PYTHON_REQUIRED_USE} ) snmp? ( python ) " # sys-apps/systemd-253 required for Type=notify-reload DEPEND=" acct-group/nut acct-user/nut dev-libs/libltdl virtual/udev cgi? ( >=media-libs/gd-2[png] ) gpio? ( dev-libs/libgpiod ) i2c? ( sys-apps/i2c-tools ) ipmi? ( sys-libs/freeipmi ) modbus? ( dev-libs/libmodbus ) python? ( ${PYTHON_DEPS} ) snmp? ( net-analyzer/net-snmp:= ) ssl? ( >=dev-libs/openssl-1:= ) systemd? ( >=sys-apps/systemd-253 ) tcpd? ( sys-apps/tcp-wrappers ) usb? ( virtual/libusb:1 ) xml? ( >=net-libs/neon-0.25.0:= ) zeroconf? ( net-dns/avahi ) " BDEPEND=" virtual/pkgconfig man? ( app-text/asciidoc ) test? ( dev-util/cppunit ) " RDEPEND=" ${DEPEND} monitor? ( $(python_gen_cond_dep ' dev-python/PyQt5[gui,widgets,${PYTHON_USEDEP}] ') ) selinux? ( sec-policy/selinux-nut ) " PATCHES=( "${FILESDIR}/${PN}-2.6.2-lowspeed-buffer-size.patch" "${FILESDIR}/systemd_notify.path" ) pkg_pretend() { if use i2c; then CONFIG_CHECK="~I2C_CHARDEV" ERROR_I2C_CHARDEV="You must enable I2C_CHARDEV in your kernel to continue" fi if use usb; then CONFIG_CHECK+=" ~HIDRAW ~USB_HIDDEV" ERROR_HIDRAW="HIDRAW is needed to support USB UPSes" ERROR_I2C_CHARDEV="USB_HIDDEV is needed to support USB UPSes" fi if use gpio; then CONFIG_CHECK="~GPIO_CDEV_V1" ERROR_GPIO_CDEV_V1="GPIO_CDEV_V1 is needed to support GPIO UPSes" fi if use serial; then CONFIG_CHECK="~SERIAL_8250" ERROR_SERIAL_8250="SERIAL_8250 is needed to support Serial UPSes" fi # Now do the actual checks setup above check_extra_config } pkg_setup() { use python && python-single-r1_pkg_setup } src_prepare() { default if [[ ${PV} == *9999 ]] ; then ./autogen.sh || die fi xdg_environment_reset } src_configure() { local myeconfargs=( --datadir=/usr/share/nut --datarootdir=/usr/share/nut --disable-static --disable-strip --disable-Werror --sysconfdir=/etc/nut --with-dev --with-drvpath="/$(get_libdir)/nut" --with-group=nut --with-htmlpath=/usr/share/nut/html --with-logfacility=LOG_DAEMON --with-statepath=/var/lib/nut --with-systemdsystemunitdir="$(systemd_get_systemunitdir)" --with-systemdtmpfilesdir="/usr/lib/tmpfiles.d" --with-udev-dir="$(get_udevdir)" --with-user=nut --without-powerman --without-python --without-python2 --with-altpidpath=/run/nut --with-pidpath=/run/nut $(use_with cgi) $(use_with gpio) $(use_with i2c linux_i2c) $(use_with ipmi freeipmi) $(use_with ipmi) $(use_with monitor nut_monitor) $(use_with python pynut) $(use_with serial) $(use_with snmp) $(use_with ssl) $(use_with systemd libsystemd) $(use_with tcpd wrap) $(use_with usb) $(use_with xml neon) $(use_with zeroconf avahi) ) filter-lto append-flags -fno-lto tc-export CC CXX AR use cgi && myeconfargs+=( --with-cgipath=/usr/share/nut/cgi ) use man && myeconfargs+=( --with-doc=man ) use python && myeconfargs+=( --with-python3="${PYTHON}" ) || myeconfargs+=( --without-python3 ) export bashcompdir="$(get_bashcompdir)" econf "${myeconfargs[@]}" } src_install() { default rm -rf "${ED}/etc/hotplug" || die find "${ED}" -name '*.la' -delete || die dodir /sbin if use cgi; then elog "CGI monitoring scripts are installed in ${EPREFIX}/usr/share/nut/cgi." elog "copy them to your web server's ScriptPath to activate (this is a" elog "change from the old location)." elog "If you use lighttpd, see lighttpd_nut.conf in the documentation." elog elog "Use script aliases according to the web server you use (apache, nginx, lighttpd, etc...)" fi # This must be done after all of the install phases local i for i in "${ED}"/etc/nut/*.sample ; do mv "${i}" "${i/.sample/}" || die done local DOCS=( AUTHORS MAINTAINERS NEWS.adoc README.adoc TODO.adoc UPGRADING.adoc ) einstalldocs if use doc; then newdoc lib/README.adoc dodoc docs/*.txt docinto cables dodoc docs/cables/* fi newinitd "${FILESDIR}"/nut-2.8.0-init.d-upsd upsd newinitd "${FILESDIR}"/nut-2.2.2-init.d-upsdrv upsdrv newinitd "${FILESDIR}"/nut-2.6.5-init.d-upsmon upsmon newinitd "${FILESDIR}"/nut-2.6.5-init.d-upslog upslog newinitd "${FILESDIR}"/nut.powerfail.initd nut.powerfail newbashcomp "${S}"/scripts/misc/nut.bash_completion upsc bashcomp_alias upsc upscmd upsd upsdrvctl upsmon upsrw if use zeroconf; then insinto /etc/avahi/services doins scripts/avahi/nut.service fi if use monitor; then make_wrapper NUT-Monitor-py3qt5 /usr/share/nut/nut-monitor/app/NUT-Monitor-py3qt5 /usr/share/nut/nut-monitor/app # Install desktop shortcut newmenu scripts/python/app/nut-monitor-py3qt5.desktop nut-monitor.desktop # Installing Application icons local res for res in 48 64 256; do doicon -s ${res} scripts/python/app/icons/${res}x${res}/nut-monitor.png done doicon -s scalable scripts/python/app/icons/scalable/nut-monitor.svg fi use python && python_optimize } pkg_postinst() { elog "Please note that NUT now runs under the 'nut' user." elog "NUT is in the uucp group for access to RS-232 UPS." elog "However if you use a USB UPS you may need to look at the udev or" elog "hotplug rules that are installed, and alter them suitably." elog elog "You are strongly advised to read the UPGRADING file provided by upstream." elog elog "Please note that upsdrv is NOT automatically started by upsd anymore." elog "If you have multiple UPS units, you can use their NUT names to" elog "have a service per UPS:" elog "ln -s /etc/init.d/upsdrv /etc/init.d/upsdrv.\$UPSNAME" elog elog 'If you want apcupsd to power off your UPS when it' elog 'shuts down your system in a power failure, you must' elog 'add nut.powerfail to your shutdown runlevel:' elog elog 'rc-update add nut.powerfail shutdown' elog optfeature "all notify events generate a global message (wall) to all users, plus they are logged via the syslog" \ sys-apps/util-linux[logger,tty-helpers] udev_reload tmpfiles_process nut-common-tmpfiles.conf xdg_pkg_postinst } pkg_postrm() { udev_reload xdg_pkg_postrm }